You have no items in your shopping cart.
Model: | IE-3400-8T2S-A |
Detail: |
Network Advantage , Switch, Managed, 8 x 10/100/1000 + 2 x Gigabit SFP, DIN rail mountable, DC power |
List Price: | |
Price: | $6,550.00 |
You Save: | $4,098.83 (38% OFF) |
Condition: | Brand New Sealed |
Availability: | SPECIAL ORDER |
Shipping: | FREE SHIPPING for all U.S orders over $100. Please call us at 201-559-1474, fill out the contact form, or chat with a live agent for other shipping methods. |
Tax: | $0.00 Tax Outside NJ and TX |
Quantity: |
The Cisco IE-3400-8T2S-A is a high-performance industrial Ethernet switch designed to deliver reliable and secure network connectivity in harsh environments. This switch features 8 Gigabit Ethernet ports and 2 SFP slots, making it an ideal solution for connecting critical industrial devices such as IP cameras, sensors, and controllers. The IE-3400-8T2S-A is engineered to operate under extreme conditions, ensuring continuous operation while offering advanced Layer 2 and Layer 3 management features for effective network segmentation, security, and traffic control.
You can check the related tab for the Cisco IE-3400-8T2S-A datasheet.
Accessories and License Upgrade PIDs | |
SD-IE-4GB= | IE 4GB SD memory card for IE |
STK-RACK-DINRAIL= | STK-RACK-DINRAIL= |
IE3400-NW-A= | Network Advantage License for IE3400, Perpetual |
IE3400-DNA-E | Cisco DNA Essentials license for IE3400 Series |
IE3400-DNA-E-3Y | IE 3400 Cisco DNA Essentials, 3 Year Term license |
IE3400-DNA-E-5Y | IE 3400 Cisco DNA Essentials, 5 Year Term license |
IE3400-DNA-E-7Y | IE 3400 Cisco DNA Essentials, 7 Year Term license |
IE3400-DNA-A | Cisco DNA Advantage license for IE3400 Series |
IE3400-DNA-A-3Y | IE 3400 Cisco DNA Advantage, 3 Year Term license |
IE3400-DNA-A-5Y | IE 3400 Cisco DNA Advantage, 5 Year Term license |
IE3400-DNA-A-7Y | IE 3400 Cisco DNA Advantage, 7 Year Term license |
LIC-MRP-MGR-XE= | MRP Ring Manager License |
LIC-MRP-CLIENT-XE= | MRP Ring Client License |
IE 3400 Series Power Supplies | |
PWR-IE50W-AC | 50W AC Power Supply |
PWR-IE50W-AC-IEC= | 50W AC-IEC Power Supply |
PWR-IE50W-AC-L | 50W AC-L Power Supply |
PWR-IE65W-PC-AC | 65W PC-AC Power Supply |
PWR-IE65W-PC-DC | 65W PC-DC Power Supply |
PWR-IE170W-PC- AC | 170W PC-AC Power Supply |
PWR-IE170W-PC- DC | 170W PC-DC Power Supply |
PWR-IE240W-PCAC-L | 240W PCAC-L Power Supply |
PWR-IE480W-PCAC-L | 480W PCAC-L Power Supply |
SFPs | |
GLC-FE-100FX-RGD= | 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX-RGD | 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100FX= | 100BASE-FX SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX= | 100BASE-LX10 SFP for Fast Ethernet SFP Ports |
GLC-FE-100EX= | 100BASE-EX for Fast Ethernet SFP Ports |
GLC-FE-100ZX= | 100BASE-ZX for Fast Ethernet SFP Ports |
GLC-FE-100BX-D= | 100BASE-BX10-D SFP for Fast Ethernet SFP Ports |
GLC-FE-100BX-U= | 100BASE-BX10-U SFP for Fast Ethernet SFP Ports |
GLC-SX-MM-RGD= | 1000BASE-SX short wavelength; rugged |
GLC-LX-SM-RGD= | 1000BASE-LX/LH long wavelength; rugged |
GLC-ZX-SM-RGD= | 1000BASE-ZX extended distance; rugged |
GLC-BX40-U-I= | 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-D-I= | 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-DA-I= | 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-U-I= | 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-D-I= | 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-SX-MMD= | 1000BASE-SX short wavelength; with DOM |
GLC-LH-SMD= | 1000BASE-LX/LH long-wavelength; with DOM |
GLC-EX-SMD= | 1000BASE-EX long-wavelength; with DOM |
GLC-ZX-SMD= | 1000BASE-ZX extended distance; with DOM |
GLC-BX-D= | 1000BASE-BX10-D downstream bidirectional single fiber; with DOM |
GLC-BX-U= | 1000BASE-BX10-U upstream bidirectional single fiber; with DOM |
GLC-BX-D-I= | 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM |
GLC-BX-U-I= | 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM |
SFP-GE-S= | Cisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm |
SFP-GE-L= | 1000BASE-LX/LH SFP (DOM) |
SFP-GE-Z= | Cisco 1000BASE-ZX SFP transceiver module for SMF |
GLC-SX-MM= | Cisco GLC_x0090_SX_x0090_MM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm |
GLC-LH-SM= | Cisco Glc Lh Sm 1000Base Lh Sm Sfp Transceiver Module |
GLC-ZX-SM= | Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, commercial operating temperature range. |
GLC-TE= | 1000BASE-T standard |
GLC-T-RGD= | 1000BASE-T standard |
CWDM-SFP-1470 | Cisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1610 | Cisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1530 | Cisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fibre Channel |
CWDM-SFP-1490 | Cisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
DWDM-SFP-3033 | 1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid) |
DWDM-SFP-3112 | 1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid) |
Specifications | IE-3400-8T2S-A |
DRAM | 4 GB |
Flash Memory | 1.5 GB |
Hardware | |
PoE power budget | Not applicable |
Removable storage | USB (Optional), SD card (Optional) |
Alarms | 2 alarms in, 1 alarm out |
Console ports | 1 RS-232 (via RJ-45), 1 USB Mini Type B |
Power inputs | Dual DC power inputs |
Number of Queues | 8 |
Forwarding Rate | Line rate for all ports and all packet sizes |
Unicast MAC addresses | 8000 |
Jumbo Frames | 2000 bytes |
No. of VLANs | 256 |
IPv4 Indirect routes | 2000 |
IPv6 Indirect routes | 512 |
Internet Group Managament Protocol (IGMP) Multicast Groups | 1000 |
Spanning Tree Protocol (STP) instances |
128 |
Access Control Entries (PACL/VACL/RACL) |
3000 |
SD card capacity (Optional) | 4 GB |
Input Voltage Range | Redundant DC input voltage: 9.6 to 60VDC |
Maximum Input Current | 6.3A |
Power Consumption | 36W |
Operating Temperature | -40°C to +70°C (40 LFM vented enclosure) -40°C to +60°C (sealed enclosure) -34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure) +85°C (type tested for 16 hours) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 15,000 feet |
Storage Altitude | 15,000 feet |
Mean Time Between Failures (MTBF) | 549,808 |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions | FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity | CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and interruptions |
Industry standards | EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850-3 Electric Substations Communications Networking EN50121-4 Railway Signaling and Telecommunications Apparatus EN50155- Railway applications - Rolling stock ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Marine I | DNC Certification according to class guideline DNV-CG-0339 Additional Standards: IEC 60945, IACS UR E10 |
Safety standards and certifications |
Information technology equipment: UL/CSA 60950-1, IEC 60950-1 CB with all country deviations UL/CSA 62368-1, IEC 62368-1 CB with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous locations: UL121201 (Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
Humidity | Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration | IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) MIL-STD-810, Method 514.4 IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
Corrosion | IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |
Properties | Cisco IE-3400-8T2S-A |
Description | Catalyst IE3400 with 8 GE Copper and 2 GE SFP, Adv. Modular, Network Advantage |
Product Family | Industrial Ethernet 3400 |
Product Type | Ethernet Switch |
Switches | |
Total Ports | 10 |
10/100/1000 RJ45 Copper Ports | 8 |
100/1000 SFP Ports | 2 |
1GE/2.5G RJ45 Copper ports | - |
Software License (Default) |
Network Advantage |
PoE/PoE (+) budget | N/A |
Software Features | |
Network Essentials License (Perpetual) |
Features |
Layer 2 Switching | IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP |
Multicast | IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier |
Managament | WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express setup, NETCONF, RESTCONF |
Security | Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS+, RADIUS server/client, MAC address notification, BPDU guard, Access Lists (PACL,VACL,RACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128, MACsec-256 |
Quality of Service (QoS) | Ingress policing, rate limit, egress queuing and shaping, auto QoS |
IPv6 | IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config SCP/SSH, Radius, TACACS+, NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard |
Layer 3 Routing | Inter-VLAN routing, Static routing |
Utility | Dying gasp, SCADA protocol classification - GOOSE messaging, MODBUS TCP/IP |
Industrial Ethernet | CIP Ethernet/IP, IEEE 1588 PTP v2 (default and power), PROFINET |
Redundancy | Resilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP |
Automation | YANG, NETCONF, RESTCONF |
Industrial Management | Layer 2 switching with 1:1 switch Network Address Translation (L2NAT) |
IOx | Container (Native docker) |
Network Advantage License (Perpetual) | Features |
IP routing Protocols | OSPF (IPv4 and IPv6), BGP (v4 and v6), RIP (V1 and V2), ISIS (v4 and v6), EIGRP (v4 and v6), Policy based routing(PBR), VRRP(v4 and v6), HSRP(v4 and v6), BFD Echo Mode for OSPFv3 |
Virtualization | Vrf-lite |
IP Multicast | PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), PIM sparse dense mode, MSDP, Multicast routing BSR (IPv4/IPv6), Auto RP(IPv4), Embedded RP(IPv6) |
(Network Advantage License includes all Network Essentials Features.) | |
Dimensions (HxWxD) Inches | 6 in. X 3.6 in. X 5.3 in. 15.2 cm. x 9.1 cm. x 13.5 cm |
Weight | 3.8 lbs (1.7 kg) |
Mounting | DIN Rail |