You have no items in your shopping cart.
Model: | IE-3400-8T2S-E |
Detail: |
Network Essentials , Switch, Managed, 8 x 10/100/1000 + 2 x Gigabit SFP, DIN rail mountable, DC power |
List Price: | |
Price: | $3,650.00 |
You Save: | $3,379.57 (48% OFF) |
Condition: | Brand New Sealed |
Availability: | SPECIAL ORDER |
Shipping: | FREE SHIPPING for all U.S orders over $100. Please call us at 201-559-1474, fill out the contact form, or chat with a live agent for other shipping methods. |
Tax: | $0.00 Tax Outside NJ and TX |
Quantity: |
The Cisco IE-3400-8T2S-E is a rugged, high-performance industrial Ethernet switch designed to provide reliable and secure network connectivity in harsh environments. This switch features 8 Gigabit Ethernet ports and 2 SFP slots, making it an ideal solution for connecting critical industrial devices such as IP cameras, sensors, and controllers. The IE-3400-8T2S-E is engineered to operate under extreme conditions, ensuring continuous operation while offering advanced Layer 2 and Layer 3 management features for effective network segmentation, security, and traffic control.
You can check the related tab for the Cisco IE-3400-8T2S-E datasheet.
Accessories and License Upgrade PIDs | |
SD-IE-4GB= | IE 4GB SD memory card for IE |
STK-RACK-DINRAIL= | STK-RACK-DINRAIL= |
IE3400-NW-A= | Network Advantage License for IE3400, Perpetual |
IE3400-DNA-E | Cisco DNA Essentials license for IE3400 Series |
IE3400-DNA-E-3Y | IE 3400 Cisco DNA Essentials, 3 Year Term license |
IE3400-DNA-E-5Y | IE 3400 Cisco DNA Essentials, 5 Year Term license |
IE3400-DNA-E-7Y | IE 3400 Cisco DNA Essentials, 7 Year Term license |
IE3400-DNA-A | Cisco DNA Advantage license for IE3400 Series |
IE3400-DNA-A-3Y | IE 3400 Cisco DNA Advantage, 3 Year Term license |
IE3400-DNA-A-5Y | IE 3400 Cisco DNA Advantage, 5 Year Term license |
IE3400-DNA-A-7Y | IE 3400 Cisco DNA Advantage, 7 Year Term license |
LIC-MRP-MGR-XE= | MRP Ring Manager License |
LIC-MRP-CLIENT-XE= | MRP Ring Client License |
IE 3400 Series Power Supplies | |
PWR-IE50W-AC | 50W AC Power Supply |
PWR-IE50W-AC-IEC= | 50W AC-IEC Power Supply |
PWR-IE50W-AC-L | 50W AC-L Power Supply |
PWR-IE65W-PC-AC | 65W PC-AC Power Supply |
PWR-IE65W-PC-DC | 65W PC-DC Power Supply |
PWR-IE170W-PC- AC | 170W PC-AC Power Supply |
PWR-IE170W-PC- DC | 170W PC-DC Power Supply |
PWR-IE240W-PCAC-L | 240W PCAC-L Power Supply |
PWR-IE480W-PCAC-L | 480W PCAC-L Power Supply |
SFPs | |
GLC-FE-100FX-RGD= | 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX-RGD | 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100FX= | 100BASE-FX SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX= | 100BASE-LX10 SFP for Fast Ethernet SFP Ports |
GLC-FE-100EX= | 100BASE-EX for Fast Ethernet SFP Ports |
GLC-FE-100ZX= | 100BASE-ZX for Fast Ethernet SFP Ports |
GLC-FE-100BX-D= | 100BASE-BX10-D SFP for Fast Ethernet SFP Ports |
GLC-FE-100BX-U= | 100BASE-BX10-U SFP for Fast Ethernet SFP Ports |
GLC-SX-MM-RGD= | 1000BASE-SX short wavelength; rugged |
GLC-LX-SM-RGD= | 1000BASE-LX/LH long wavelength; rugged |
GLC-ZX-SM-RGD= | 1000BASE-ZX extended distance; rugged |
GLC-BX40-U-I= | 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-D-I= | 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-DA-I= | 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-U-I= | 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-D-I= | 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-SX-MMD= | 1000BASE-SX short wavelength; with DOM |
GLC-LH-SMD= | 1000BASE-LX/LH long-wavelength; with DOM |
GLC-EX-SMD= | 1000BASE-EX long-wavelength; with DOM |
GLC-ZX-SMD= | 1000BASE-ZX extended distance; with DOM |
GLC-BX-D= | 1000BASE-BX10-D downstream bidirectional single fiber; with DOM |
GLC-BX-U= | 1000BASE-BX10-U upstream bidirectional single fiber; with DOM |
GLC-BX-D-I= | 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM |
GLC-BX-U-I= | 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM |
SFP-GE-S= | Cisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm |
SFP-GE-L= | 1000BASE-LX/LH SFP (DOM) |
SFP-GE-Z= | Cisco 1000BASE-ZX SFP transceiver module for SMF |
GLC-SX-MM= | Cisco GLC_x0090_SX_x0090_MM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm |
GLC-LH-SM= | Cisco Glc Lh Sm 1000Base Lh Sm Sfp Transceiver Module |
GLC-ZX-SM= | Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, commercial operating temperature range. |
GLC-TE= | 1000BASE-T standard |
GLC-T-RGD= | 1000BASE-T standard |
CWDM-SFP-1470 | Cisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1610 | Cisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1530 | Cisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fibre Channel |
CWDM-SFP-1490 | Cisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
DWDM-SFP-3033 | 1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid) |
DWDM-SFP-3112 | 1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid) |
Specifications | IE-3400-8T2S-E |
DRAM | 4 GB |
Flash Memory | 1.5 GB |
Hardware | |
PoE power budget | Not applicable |
Removable storage | USB (Optional), SD card (Optional) |
Alarms | 2 alarms in, 1 alarm out |
Console ports | 1 RS-232 (via RJ-45), 1 USB Mini Type B |
Power inputs | Dual DC power inputs |
Number of Queues | 8 |
Forwarding Rate | Line rate for all ports and all packet sizes |
Unicast MAC addresses | 8000 |
Jumbo Frames | 2000 bytes |
No. of VLANs | 256 |
IPv4 Indirect routes | 2000 |
IPv6 Indirect routes | 512 |
Internet Group Managament Protocol (IGMP) Multicast Groups | 1000 |
Spanning Tree Protocol (STP) instances |
128 |
Access Control Entries (PACL/VACL/RACL) |
3000 |
SD card capacity (Optional) | 4 GB |
Input Voltage Range | Redundant DC input voltage: 9.6 to 60VDC |
Maximum Input Current | 6.3A |
Power Consumption | 36W |
Operating Temperature | -40°C to +70°C (40 LFM vented enclosure) -40°C to +60°C (sealed enclosure) -34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure) +85°C (type tested for 16 hours) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 15,000 feet |
Storage Altitude | 15,000 feet |
Mean Time Between Failures (MTBF) | 549,808 |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions | FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity | CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and interruptions |
Industry standards | EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850-3 Electric Substations Communications Networking EN50121-4 Railway Signaling and Telecommunications Apparatus EN50155- Railway applications - Rolling stock ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Marine I | DNC Certification according to class guideline DNV-CG-0339 Additional Standards: IEC 60945, IACS UR E10 |
Safety standards and certifications |
Information technology equipment: UL/CSA 60950-1, IEC 60950-1 CB with all country deviations UL/CSA 62368-1, IEC 62368-1 CB with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous locations: UL121201 (Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
Humidity | Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration | IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) MIL-STD-810, Method 514.4 IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
Corrosion | IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |
Properties | Cisco IE-3400-8T2S-E |
Description | Catalyst IE3400 with 8 GE Copper and 2 GE SFP, Adv. Modular, Network Essentials |
Product Family | Industrial Ethernet 3400 |
Product Type | Ethernet Switch |
Switches | |
Total Ports | 10 |
10/100/1000 RJ45 Copper Ports | 8 |
100/1000 SFP Ports | 2 |
1GE/2.5G RJ45 Copper ports | - |
Software License (Default) | Network Essentials |
PoE/PoE (+) budget | N/A |
Software Features | |
Network Essentials License (Perpetual) |
Features |
Layer 2 Switching | IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP |
Multicast | IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier |
Managament | WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express setup, NETCONF, RESTCONF |
Security | Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS+, RADIUS server/client, MAC address notification, BPDU guard, Access Lists (PACL,VACL,RACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128 |
Quality of Service (QoS) | Ingress policing, rate limit, egress queuing and shaping, auto QoS |
IPv6 | IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config SCP/SSH, Radius, TACACS+, NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard |
Layer 3 Routing | Inter-VLAN routing, Static routing |
Utility | Dying gasp, SCADA protocol classification - GOOSE messaging, MODBUS TCP/IP |
Industrial Ethernet | CIP Ethernet/IP, IEEE 1588 PTP v2 (default and power), PROFINET |
Redundancy | Resilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP |
Automation | YANG, NETCONF, RESTCONF |
Industrial Management | Layer 2 switching with 1:1 switch Network Address Translation (L2NAT) |
IOx | Container (Native docker) |
Dimensions (HxWxD) Inches | 6 in. X 3.6 in. X 5.3 in. 15.2 cm. x 9.1 cm. x 13.5 cm |
Weight | 3.8 lbs (1.7 kg) |
Mounting | DIN Rail |