You have no items in your shopping cart.
Model: | IE-2000-16T67P-G-E |
Detail: | Cisco IE-2000-16T67P-G-E Industrial Ethernet Switch The Cisco IE-2000-16T67P-G-E is a high-performance industrial Ethernet switch designed to provide reliable and secure network connectivity in demanding environments. This switch features 16 Gigabit |
Price: | $3,575.00 |
Condition: | Brand New Sealed |
Availability: | Out of Stock |
Shipping: | FREE SHIPPING for all U.S orders over $100. Please call us at 201-559-1474, fill out the contact form, or chat with a live agent for other shipping methods. |
Tax: | $0.00 Tax Outside NJ and TX |
Quantity: |
The Cisco IE-2000-16T67P-G-E is a high-performance industrial Ethernet switch designed to provide reliable and secure network connectivity in demanding environments. This switch features 16 Gigabit Ethernet ports and 6 Fast Ethernet PoE ports, making it ideal for connecting and powering industrial devices such as IP cameras, sensors, and controllers. The IE-2000-16T67P-G-E is built to withstand extreme conditions, ensuring continuous operation in harsh industrial settings while offering essential Layer 2 management features for effective network segmentation and traffic control.
You can check the related tab for the Cisco IE-2000-16T67P-G-E datasheet.
Connectors and cabling | |
Data cable | ● Copper 100 Base-T M12 D coded 4-pole (pin) cable connector ● Copper GE M12 X coded-8-pole (pin)-cable connector |
Alarm cable | ● M12 A-Coded 5-Pin Cable |
Console cable | ● M12 A Coded 5-Pin connector |
Power supply cables | ● Power cable for power source, Mini-Change A-Size single-ended cord set, 4 poles, female to pigtail, 16 AWG PVC cable. Molex part#130006-0737 ● Power cable to IE2000 IP67 switch: Mini-Change A-size double-Ended Cordset, 4 poles male to female. 16 AWG, TPE cable. Molex Part #130010-0863 ● Power cable for AC-DC power source, Mini-change A-size single-ended cord set, 3 pins, female insert on one end to pigtail, 16 AWG PVC cable, Molex part# 130006-2419 ● Power cord from power source to power supply: 2 hole female power cord to open for input DC connector. Molex Part #130006-2419 |
Cisco IE 2000 Cisco DNA license | |
IE2000-DNA-E-L | Cisco DNA Essentials license (up to 12 ports) |
IE2000-DNA-E-L-3Y | Cisco DNA Essentials 3-year term license (up to 12 ports) option |
IE2000-DNA-E-L-5Y | Cisco DNA Essentials 5-year term license (up to 12 ports) option |
IE2000-DNA-E-L-7Y | Cisco DNA Essentials 7-year term license (up to 12 ports) option |
IE2000-DNA-E-M | Cisco DNA Essentials license (up to 24 ports) |
IE2000-DNA-E-M-3Y | Cisco DNA Essentials 3-year term license (up to 24 ports) option |
IE2000-DNA-E-M-5Y | Cisco DNA Essentials 5-year term license (up to 24 ports) option |
IE2000-DNA-E-M-7Y | Cisco DNA Essentials 7-year term license (up to 24 ports) option |
Specifications | Cisco IE-2000-16T67P-G-E Switch |
Total ports | 18 |
100 MB D-code | 16 |
GE X-code ports | 2 GE |
Manufacturing license | LAN Base |
IEEE1588 | X |
NAT | X (Requires LAN Base to LAN Enhanced image (enables Layer 2 NAT)) |
PoE (+) | X |
Hardware | ● 256MB DRAM with ECC memory |
● IEEE 1588v2 FPGA | |
● 64MB on-board flash memory | |
● 1GB removable SD flash memory card (optional) | |
Alarm | ● Alarm-one alarm output relay using an M12 A Coded 5 Pin connector (Max. rated: 24VDC @ |
1A/48VDC @ 0.5A) | |
Input voltage supported | with PoE: 44-57VDC, with PoE+ 50-57VDC |
Dimensions (H x W x D) | 9.5” x 11.84” x 3.2” (241.7 x 300.7 x 81.5 mm) |
Weight | 7.28 lbs. (3.30 kg) |
Cisco IE 2000 software features - LAN Base license (Default) | |
Layer 2 switching | IEEE 802.1, 802.3, 802.3at, 802.3af standard (see Table 8), VTPv2, NTP, UDLD, CDP, LLDP, |
Unicast MAC filter, Flex Link, REP, VTPv3, EtherChannel, Voice VLAN | |
Security | SCP, SSH, SNMPv3, TACACS+, RADIUS Server/Client, MAC Address Notification, BPDU |
Guard, SPAN session (1), Port-Security, DHCP Snooping, Dynamic ARP Inspection, IP | |
Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain | |
Authentication, Storm Control, Trust Boundary | |
Multicast | IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier |
QoS | IPv4 Ingress Policing, Rate-Limiting, Egress Queuing/Shaping, AutoQoS |
Management | Fast Boot, Express Setup, Web Device Manager, CNA, Cisco Prime, LMS, MIB, SmartPort, |
SNMP, syslog, Port- Based DHCP, Storm Control-Unicast, Multicast, Broadcast, SPAN | |
Sessions (2), RSPAN, DHCP Server, Customized TCAM/SDM Size Configuration | |
Industrial Ethernet | Ethernet/IP, Profinet, Profinet MRP, IEEE 1588 PTPv2 |
IPv4 routing | IPv4 static routing |
IPv6 routing | IPv6 host support, HTTP over IPv6, SNMP over IPv6 |
Industrial Management (Enhanced LAN Base) | Layer 2 Switching with 1:1 static NAT |
(IP Lite license) IPv4 Routing | RIP, OSPF, EIGRP, VRF Lite |
(IP Lite license) IPv6 Routing | IPv6 Static routing, OSPFv3 |
Compliance specifications | |
Safety certifications | ● UL/CSA 60950-1 |
● EN 60950-1 | |
● CB to IEC 60950-1 with all country deviations | |
● NOM to NOM-019-SCFI (through partners and distributor) | |
● CCC (for power supply only) (Pending) | |
Industrial (control equipment) floor | ● UL 508 |
● CSA C22.2, No 142 | |
● CSA C22, 2 No 107.1 (for Power Supply Only) | |
Operating environment | ● Operating Temperature: -40C to +60C |
● EN 60068-2-1 | |
● EN 60068-2-2 | |
● EN 61163 | |
● Altitude: Up to 13,800 feet or 4,200 meters | |
EMC emissions and | ● FCC 47 CFR Part 15 Class A |
immunity compliance | ● EN 55011 |
● EN 55022A Class A | |
● VCCI Class A | |
● AS/NZS CISPR 22 Class A | |
● CISPR 11 Class A | |
● CISPR 22 Class A | |
● ICES 003 Class A | |
● CNS13438 Class A | |
● KN22 | |
● EN55024 | |
● CISPR 24 | |
● AS/NZS CISPR 24 | |
● KN24 | |
● Brazil ANATEL certification | |
● EN 61000-4-2 Electro Static Discharge | |
● EN 61000-4-3 Radiated RF | |
● EN 61000-4-4 Electromagnetic Fast Transients | |
● EN 61000-4-5 Surge | |
● EN 61000-4-6 Conducted RF | |
● EN 61000-4-8 Power Frequency Magnetic Field | |
● EN 61000-4-9 Pulse Magnetic Field | |
● EN 61000-4-10 Oscillatory Magnetic Field | |
● EN-61000-4-29 DC Power Voltage Dips and Immunity | |
Shock and vibration | ● IEC 60068-2-6 Vibration: IEC 60068-2-6, IEC 255 21.1 Class 1 Vibration Test |
● IEC 60068-2-27 (Shock) | |
● IEC 60068-2-31 (Shock) | |
● IEC 60068-2-32 (Shock) | |
● IEC 60068-2-64 (Vibration) | |
● EN 61373 Cat 1 Class B (Shock and Vibration) | |
Industry standards | ● EN 61000-6-2 Industrial |
● EN 61000-6-4 Industrial | |
● EN 61000-6-1 Light Industrial | |
● EN 61326 Industrial Control | |
● EN 61131-2 Programmable Controllers | |
● Marine (DnV) ENV3 (Pending) | |
● EN 60945 Maritime navigation and radio equipment and systems (Pending) | |
● IEEE 1613 Electric Power Stations Communications Networking (Pending) | |
● IEC 61850-3 Electric Substations Communications Networking (Pending) | |
◦ EN 50155 EMC, EMI Environmental and Mechanical, galvanic isolation on uplinks (g1/1 g1/2) only | |
● EN 45545-3 Fire Safety in Railway Vehicles | |
● EN 45545-2 Fire Protection | |
● EN50121-4 Railway-Signaling and Telecommunications Apparatus | |
● EN50121-3-2 Railway-Apparatus for Rolling Stock | |
● NEMA TS-2 DC Power Traffic Control Equipment (Pending) | |
● ODVA Industrial EtherNet/IP | |
● ABB Industrial IT Certificate | |
● IP67 (per EN60529) | |
● NEMA 4 (per UL 50E) | |
Corrosive testing | ● ISO 9223: Corrosion |
● class C3-Medium | |
● ISO 9223: Corrosion | |
● class C4-High | |
● EN 60068-2-52 Salt mist testing | |
Humidity | ● IEC 60068-52-2 (Salt Fog Mist, Test Kb) marine environments |
● IEC 60068 -2-3 | |
● IEC 60068-2-30 | |
● Relative humidity: 5% to 95% noncondensing | |
Operating temperature | ● -40°C to +75°C |
● -40°C to +70°C (vented enclosure operating) | |
● -40°C to +60°C (sealed enclosure operating) | |
● -34°C to +75°C (200 LFM or more fan- or blower-equipped enclosure operating) | |
● -40°C to +85°C (type tested to +85°C for 16 hours) | |
● Altitude: Up to 13,800 feet (4570 meters) | |
Storage temperature | ● -40°C to +85°C |
● IEC 60068-2-14 | |
● Altitude: Up to 13,800 feet or 4,200 meters | |
MTBF | ● Mean time between failures: 374,052 hours (42.7 years) |
Management and Standards | |
IEEE standards | ● IEEE 802.1D MAC Bridges, STP |
● IEEE 802.1p Layer2 COS Prioritization | |
● IEEE 802.1q VLAN | |
● IEEE 802.1s Multiple Spanning-Trees | |
● IEEE 802.1w Rapid Spanning-Tree | |
● IEEE 802.1x Port Access Authentication | |
● IEEE 802.1AB LLDP | |
● IEEE 802.3ad Link Aggregation (LACP) | |
● IEEE 802.3af Power over Ethernet provides up to 15.4W DC power to each end device | |
● IEEE 802.3at Power over Ethernet provides up to 25.5W DC power to each end device | |
● IEEE 802.3af Power over Ethernet | |
● IEEE 802.3at Power over Ethernet Plus | |
● IEEE 802.3x full duplex on 10Base-T | |
● IEEE 802.3 10BASE-T specification | |
● IEEE 802.3u 100BASE-TX specification | |
● IEEE 802.3ab 1000BASE-T specification | |
● IEEE 1588v2 PTP Precision Time Protocol | |
RFC compliance | ● RFC 768: UDP |
● RFC 783: TFTP | |
● RFC 791: IPv4 protocol | |
● RFC 792: ICMP | |
● RFC 793: TCP | |
● RFC 826: ARP | |
● RFC 854: Telnet | |
● RFC 951: BootP | |
● RFC 959: FTP | |
● RFC 1157: SNMPv1 | |
● RFC 1901, 1902-1907 SNMPv2 | |
● RFC 2273-2275: SNMPv3 | |
● RFC 2571: SNMP Management | |
● RFC 1166: IP Addresses | |
● RFC 1256: ICMP Router Discovery | |
● RFC 1305: NTP | |
● RFC 1492: TACACS+ | |
● RFC 1493: Bridge MIB Objects | |
● RFC 1534 DHCP and BootP interoperation | |
● RFC 1542: Bootstrap Protocol | |
● RFC 1643: Ethernet Interface MIB | |
● RFC 1757: RMON | |
● RFC 2068: HTTP | |
● RFC 2131, 2132: DHCP | |
● RFC 2236: IGMP v2 | |
● RFC 3376: IGMP v3 | |
● RFC 2474: DiffServ Precedence | |
● RFC 3046: DHCP Relay Agent Information Option | |
● RFC 3580: 802.1x RADIUS | |
● RFC 4250-4252 SSH Protocol | |
SNMP MIB objects | ● BRIDGE-MIB |
● CALISTA-DPA-MIB | |
● CISCO-ACCESS-ENVMON-MIB | |
● CISCO-ADMISSION-POLICY-MIB | |
● CISCO-AUTH-FRAMEWORK-MIB | |
● CISCO-BRIDGE-EXT-MIB | |
● CISCO-BULK-FILE-MIB | |
● CISCO-CABLE-DIAG-MIB | |
● CISCO-CALLHOME-MIB | |
● CISCO-CAR-MIB | |
● CISCO-CDP-MIB | |
● CISCO-CIRCUIT-INTERFACE-MIB | |
● CISCO-CLUSTER-MIB | |
● CISCO-CONFIG-COPY-MIB | |
● CISCO-CONFIG-MAN-MIB | |
● CISCO-DATA-COLLECTION-MIB | |
● CISCO-DHCP-SNOOPING-MIB | |
● CISCO-SNMP-TARGET-EXT-MIB | |
● CISCO-STACK-MIB | |
● CISCO-STACKMAKER-MIB | |
● CISCO-STP-EXTENSIONS-MIB | |
● CISCO-SYSLOG-MIB | |
● CISCO-TCP-MIB | |
● CISCO-UDLDP-MIB | |
● CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB | |
● CISCO-VLAN-MEMBERSHIP-MIB | |
● CISCO-VTP-MIB | |
● ENTITY-MIB | |
● ETHERLIKE-MIB | |
● HC-RMON-MIB | |
● IEEE8021-PAE-MIB | |
● IEEE8023-LAG-MIB | |
● IF-MIB | |
● IP-FORWARD-MIB | |
● CISCO-ENTITY-ALARM-MIB | |
● CISCO-ENTITY-VENDORTYPE-OID-MIB | |
● CISCO-ENVMON-MIB | |
● CISCO-ERR-DISABLE-MIB | |
● CISCO-FLASH-MIB | |
● CISCO-FTP-CLIENT-MIB | |
● CISCO-IF-EXTENSION-MIB | |
● CISCO-IGMP-FILTER-MIB | |
● CISCO-IMAGE-MIB | |
● CISCO-IP-STAT-MIB | |
● CISCO-LAG-MIB | |
● CISCO-LICENSE-MGMT-MIB | |
● CISCO-MAC-AUTH-BYPASS-MIB | |
● CISCO-MAC-NOTIFICATION-MIB | |
● CISCO-MEMORY-POOL-MIB | |
● CISCO-PAE-MIB | |
● CISCO-PAGP-MIB | |
● CISCO-PING-MIB | |
● CISCO-PORT-QOS-MIB | |
● CISCO-PORT-SECURITY-MIB | |
● CISCO-PORT-STORM-CONTROL-MIB | |
● CISCO-PROCESS-MIB | |
● CISCO-PRODUCTS-MIB | |
● CISCO-RESILIENT-ETHERNET- PROTOCOL- MIB | |
● CISCO-RTTMON-ICMP-MIB | |
● CISCO-RTTMON-IP-EXT-MIB | |
● CISCO-RTTMON-MIB | |
● CISCO-RTTMON-RTP-MIB | |
● IP-MIB | |
● LLDP-EXT-MED-MIB | |
● LLDP-MIB | |
● NETRANGER | |
● NOTIFICATION-LOG-MIB | |
● OLD-CISCO-CHASSIS-MIB | |
● OLD-CISCO-CPU-MIB | |
● OLD-CISCO-FLASH-MIB | |
● OLD-CISCO-INTERFACES-MIB | |
● OLD-CISCO-IP-MIB | |
● OLD-CISCO-MEMORY-MIB | |
● OLD-CISCO-SYS-MIB< | |
● OLD-CISCO-SYSTEM-MIB | |
● OLD-CISCO-TCP-MIB | |
● OLD-CISCO-TS-MIB | |
● RMON-MIB | |
● RMON2-MIB | |
● SMON-MIB | |
● SNMP-COMMUNITY-MIB | |
● SNMP-FRAMEWORK-MIB | |
● SNMP-MPD-MIB | |
● SNMP-NOTIFICATION-MIB | |
● SNMP-PROXY-MIB | |
● SNMP-TARGET-MIB | |
● SNMP-USM-MIB | |
● SNMP-VIEW-BASED-ACM-MIB | |
● SNMPv2-MIB | |
● TCP-MIB | |
● UDP-MIB | |
Properties | Cisco IE-2000-16T67P-G-E Switch |
Description | The Cisco IE-2000-16T67P-G-E Switch is a rugged industrial Ethernet solution with 16 Gigabit Ethernet ports, including 6 Power over Ethernet (PoE) ports. Ideal for demanding environments, it ensures robust connectivity for industrial applications, making it well-suited for manufacturing, transportation, and utility deployments. |
Product Family | Cisco Industrial Ethernet 2000 IP67 Series Switches |
Product Type | Switch |
IE 2000 IP67 product highlights | |
Certified IP67 rating | The solution is IP67-rated to protect against dust and submersion in water. It meets the most rigorous industrial and safety standards for extreme temperature and vibration, humidity, electromagnetic emissions, and other factors. |
Compliant with industrial automation standards |
The rugged switch supports EtherNet/IP (CIP) and PROFINET so you can easily integrate it with any Ethernet-based industrial equipment and management system. It also supports Precision Time Protocol (PTP) v2 for demanding synchronized applications. |
Easy deployment | With zero-touch discovery using Dynamic Host Control Protocol (DHCP), express setup, and sub-60-second boot-up times, you can easily migrate to all-IP-over-Ethernet networking environment. |
Strong endpoint security | Support for the following: ● 802.1x ● Port security ● Dynamic port-based authentication using DHCP ● Encrypted administrative traffic ● Centralized authentication |
Resiliency | Cisco brings recovery mechanisms such as flex links and Cisco Resilient Ethernet Protocol (REP) to the factory floor or other industrial site. Profinet MRP ring provides the open standard industrial resiliency. |
Manageability | Cisco DNA Center enables centralized automation and assurance at scale with a Cisco DNA Essentials 3-year or 5-year or 7-year term-based subscription license. ● The solution is easy for operations staff to configure and manage. Cisco Auto Smart Port lets you configure the right Quality of Service (QoS) settings for any port in seconds. It also allows for secure web-based administration and easy integration with your network management system. |
Network Address Translation (NAT) |
The switches provide line-rate, hardware-enabled static address translation to easily connect complex Layer- 2/machine node networks. |
Industrial Power-over-Ethernet (PoE) | Select switch models let you connect and power endpoints with a single cable in compliance with PoE and PoE+ standards. |
Removable SD flash memory |
With tightly secured swappable hard drives, you can quickly replace switches in the field with minimal disruption. |
Platform flexibility | The Cisco IE2000 IP67 Series is available with 8, 16, or 24 10/100 Base-T, fixed configuration Ethernet ports and 2x Gigabit Ethernet ports. It provides M12 D Coded, X Coded, and a mini-change dual-power connector in an industrial-hardened, wallmountable form factor. |