| Specifications |
Cisco Catalyst IR1101 Rugged Series Router |
| Memory |
| Default and maximum DRAM |
4 GB |
| Default and maximum Flash memory |
8 GB (physical) / 4 GB (usable) |
| Ingress protection rating |
IP30 |
| Physical characteristics |
Physical dimensions (H x W x D) Chassis
Expansion Module (IRM-1100-SP or IRM-1100-SPMI)
Expansion Module (IRM-1100- 4A2T) |
2.36 in. x 5.22 in. x 4.92 in. (60 x 132.5 x 124.9 mm)
1.3 in. x 5.2 in. x 4.9 in. (33 x 132 x 124 mm)
0.9 in. x 5.2 in. x 4.9 in. (23 x 132 x 124 mm) |
Weight Chassis Expansion Module ● IRM-1100-SPMI: ● IRM-1100-SP: ● IRM-1100-4A2T: |
2.25 lbs (1.02 kg)
1.65 lbs (0.75 kg) 1.45 lbs (0.66 kg) 0.94 lbs (0.43 kg) |
| Mounting options |
Panel, wall, and din rail (vertical and horizontal) mount |
| Power specifications |
Nominal voltage: +/-12V to +/-48V DC Minimum and maximum input voltage: 9.6-60V DC Maximum and minimum input current: 1.24A (9.6V DC) and 0.26A (60V DC) |
| Power consumption |
At idle: 6.6W Typical: 9.8W Maximum: 12W Additional 10W (typical) with expansion module and 2nd cellular |
| Interfaces on the base platform |
| Console |
Mini type-B USB |
| WAN interfaces |
● Combo 10/100/1000 Gigabit Ethernet port (RJ45 and SFP) on the base platform ● An additional 10/100/1000 Gigabit Ethernet SFP on the expansion module. Refer to Table 8 for supported SFPs ● LTE: Modular with options for single and dual active LTE and LTE-Advanced |
| LAN interfaces |
● Four 10/100BASE-T Fast Ethernet ports |
| Input and output |
● ALARM input port |
| Interfaces on Serial and Ethernet Expansion Module |
| Serial Interfaces |
● 4 x Isolated asynchronous serial ports (RS232/RS485/RS422)(DCE) |
| Ethernet Interfaces |
● 2 x GE RJ45 LAN ports |
| LEDs |
● System OK ● Link for Ethernet WAN ports ● VPN ● Tricolor user-configurable LED ● ALARM |
| Serial interface |
● Isolated RS-232 RJ45 DTE port ● Support for asynchronous mode with speeds up to 115,200 baud |
| Serial protocols |
SCADA, DNP3, T101-104, Raw Socket TCP, and UDP |
| Environmental characteristics |
Environmental operating temperature range |
–40 to 140°F (–40 to 60°C) in a sealed NEMA cabinet with no airflow –40 to 158°F (–40 to 70°C) in a vented cabinet with 40 Linear Feet per Minute (LFM) of air –40 to 167°F (–40 to 75°C) in a forced air enclosure with 200 LFM of air Type tested at 85°C for 16 hours |
| Operating altitude |
40°C up to 13,800 ft (operating) per IEC 68-2-41 |
| Non-operating shock and vibration |
● 50-60G (3.76 m/s minimum) ● 3-500Hz at 1.12 GRMS (BP at 10 and 100 Hz) |
| Standard safety certifications |
● UL 60950-1, 2nd edition ● CAN/CSA C22.2 No. 60950-1, 2nd edition ● EN 60950-1, 2nd edition ● CB to IEC 60950-1, 2nd edition with all group differences and national deviations |
| Hazardous locations standards |
● ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) ● CSA 213 (Class 1, Div 2 A-D) ● IEC 60079-0 and -15 IECEx test report (Class I, Zone 2, gas groups IIC) ● EN 60079-0 and -15 ATEX certification (Class I, Zone 2, gas groups IIC) |
| Industry standards |
Public Safety: ● FirstNet Ready™ ● Verizon Frontline Smart Grid: ● IEC 61850-3 ● IEEE 1613 Security: ● FIPS 140-2 ● Common Criteria Department of Defense ● DoDIN APL IPv6 ● USGv6 |
| EMC emissions CLASS A |
● 47 CFR Part 15 B ● EN 55032:2015 ● CISPR 32 Edition 2 ● CNS13438: 2006 ● EN 300 386 V1.6.1 ● ICES-003 Issue 6: 2016 ● KN 32: 2015 ● TCVN 7189: 2009 ● V-2/2015.04 ● V-3/2015.04 ● AS/NZ CISPR32 |
| EMC immunity |
● EN 61000-4-2, 3, 4, 5, 6, 8, 9, 16, 17, 18, and 29 ● CISPR24: 2010 + A1: 2015 ● EN 300 386 V1.6.1 ● EN 55024: 2010 + A1: 2015 ● EN 55035:2017 ● KN35: 2015 ● TCVN 7317:2003 ● QCVN 18:2014 |