| Specifications |
C8200L-1N-4T |
| Description |
C8200L 1RU w/ 1 NIM slot and 4x 1 Gigabit Ethernet WAN ports |
| 1G port density |
4 |
| Slots |
1 NIM 1 PIM |
| Memory (DRAM) default |
4 GB |
| Storage (M.2 SSD) default |
No |
| SD-WAN IPsec throughput (1400 bytes) |
Up to 500 Mbps |
| SD-WAN IPsec throughput (IMIX*) |
400 Mbps |
| SD-WAN overlay tunnels scale |
1500 |
| *IMIX is average packet size of 352 bytes. |
| IPv4 forwarding throughput (1400 bytes) |
Up to 3.8 Gbps |
| IPsec throughput (1400 bytes) |
Up to 500 Mbps |
| Number of IPsec Static Virtual Tunnel Interface (SVTI) tunnels |
1500 |
| Number of Access Control Lists (ACLs) per system |
4000 |
| Number of IPv4 Access Control Entries (ACEs) per system |
72,000 |
| Number of IPv4 routes |
800,000 with default 4 GB, up to 4M with 32 GB |
| Number of IPv6 routes |
800,000 with default 4 GB, up to 4M with 32 GB |
| Number of queues |
16,000 |
| Number of Network Address Translation (NAT) sessions |
600,000 with default 4 GB, up to 2M with 32 GB |
| Number of firewall sessions |
512,000 |
| Number of Virtual Route Forwarding (VRF) instances |
2000 |
| Minimum software requirement |
Cisco IOS XE Software Release 17.5.1 |
| Security |
Built-in end-to-end segmentation (VPNs), ZBFW, PKI, Cisco DNA Layer Security, SIG |
| Dimensions (H x W x D) |
1.73 x 17.25 x 11.8 in. (4.39 x 43.81 x 29.97 cm) |
| Rack Units (RU) |
1 RU |
| Chassis weight |
10 lb (4.54 kg) |
| Input voltage |
AC: 90 to 264 VAC |
| Operating temperature |
32° to 104°F (0° to 40°C) |
| Storage temperature |
(-40° to 150°F) (-40° to 70°C) |
Acoustics: Sound pressure (Typical/maximum) |
69 dBA |
Acoustics: Sound power (Typical/maximum) |
80 dBA |
Relative humidity operating and nonoperating noncondensing |
Ambient (noncondensing) operating: 5% to 85% Ambient (noncondensing) nonoperating and storage: 5% to 95% |
| Altitude |
0 to 10,000 feet (0 to 3050 meters) |
Mean Time Between Failures (MTBF) |
692,577 hours |
| Safety certifications |
UL 60950-1 CAN/CSA-C22.2 No. 60950-1 EN 60950-1 IEC 60950-1 AS/NZS 60950-1 IEC/EN 60825 Laser Safety FDA: Code of Federal Regulations Laser Safety |
| EMC (emissions) |
47 CFR Part 15 Class A ICES 003 Class A AS/NZS CISPR 32 Class A CISPR 32 Class A EN55032 Class A VCCI-CISPR 32 Class A CNS-13438 Class A KN32 Class A IEC/EN 61000-3-2: Power Line Harmonics IEC/EN 61000-3-3: Voltage Fluctuations and Flicker |
| EMC (immunity) |
IEC/EN-61000-4-2: Electrostatic Discharge Immunity IEC/EN-61000-4-3: Radiated Immunity IEC/EN-61000-4-4: Electrical Fast Transient Immunity IEC/EN-61000-4-5: Surge AC, DC, and Signal Ports IEC/EN-61000-4-6: Immunity to Conducted Disturbances IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations KN35 |
| EMC (ETSI/EN) |
EN300 386: Telecommunications Network Equipment (EMC) EN55032: Multimedia Equipment (Emissions) EN55024: Information Technology Equipment (Immunity) EN55035: Multimedia Equipment (Immunity) EN61000-6-1: Generic Immunity Standard |