Part Number: AP8870

Technical Details

30A 0U Vertical PDU, 16x NEMA 5-20R, 12x C13, 2x C19 Outlets, Active Metering, Secure Remote Access
$1,708.00
$1,124.00
34% OFF
You Save: $584.00
-
+

[accessories]

Installation Guide Included in the box
Rack Mounting Brackets Included in the box
Serial Configuration Cable Included in the box
Safety Guide Included in the box
Warranty Card Not specified
[/accessories]

Overview

The APC NetShelter AP8870 Metered Rack PDU provides precision power monitoring for data centers and IT racks. Featuring 30A input with 0U vertical mounting, it delivers accurate energy data, user-defined thresholds, and proactive alerts to ensure uptime and efficiency. Designed for scalability, it integrates with APC centralized management platforms for streamlined oversight.

Key Features & Benefits

  • Active Metering: Real-time visibility into energy consumption enables optimized load balancing.
  • User-Defined Alarms: Configurable thresholds send instant alerts to prevent overloads.
  • Outlet Diversity: Equipped with 16 NEMA 5-20R, 12 C13, and 2 C19 outlets for flexible deployments.
  • Secure Remote Access: Manage via Web, SNMP, or Telnet with APC InfraStruxure integration.
  • Space-Saving Design: 0U vertical rack mounting preserves rack unit capacity.

Technical Deep Dive

The AP8870 employs advanced metering technology to provide detailed insight into circuit utilization. By delivering real-time data, IT managers can avoid overloads and optimize rack density without guesswork.

Its secure management options include SNMP, Telnet, and Web interfaces, ensuring both local and remote accessibility. Combined with APC’s InfraStruxure suite, it offers a centralized view of power health across multiple racks.

The ultra-low-profile circuit breakers and locking IEC outlets enhance operational safety and reliability, making it a dependable choice for enterprise environments.

Ideal Applications

  • Enterprise data centers requiring detailed energy monitoring
  • Server racks with diverse outlet requirements
  • Colocation facilities demanding proactive overload prevention
  • IT environments using APC InfraStruxure for management

Frequently Asked Questions (FAQs)

Q1: How is the AP8870 installed?
A: It is a 0U vertical rack-mounted PDU with included brackets for easy side mounting in racks.

Q2: What power capacity does it provide?
A: The PDU supports 30A input with a 4992 VA load capacity. Runtime depends on connected UPS systems and load distribution.

Q3: How can it be managed?
A: It supports Web, SNMP, and Telnet interfaces and integrates seamlessly with APC InfraStruxure for centralized monitoring.

Properties

Brand APC by Schneider Electric
Model AP8870
Product Type NetShelter Metered Rack PDU
Form Factor 0U Vertical
Dimensions (H x W x D) 70.5" x 2.2" x 1.7" (1791 x 55 x 44 mm)
Weight 14.07 lb (6.38 kg)
Color Black
Number of Rack Units 0U
Mounting Mode Rack-mounted (Vertical, Side Mountable)
Cooling Passive

Specifications

PDU Type Metered
Input Voltage 120 V / 208 V
Output Voltage 120 V / 208 V / 240 V
Input Plug Type NEMA L14-30P
Input Frequency 50/60 Hz
Line Rated Current 24 A (Max 30 A)
Load Capacity 4992 VA
Outlets 16 × NEMA 5-20R, 12 × IEC C13, 2 × IEC C19
Communication Ports Web, SNMP, Telnet
Operating Temperature 23–140 °F (-5–60 °C)
Storage Temperature -13–149 °F (-25–65 °C)
Operating Humidity 5–95% non-condensing
Storage Humidity 5–95% non-condensing
Operating Altitude 0–10,000 ft
Storage Altitude 0–50,000 ft
Compliance cUL Listed, UL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, RoHS, REACh
Warranty 2 years repair or replace

Shipping

INTERNATIONAL -

International buyers must acknowledge that all duties and taxes are their sole responsibility and Network Devices Inc is not held responsible for possible additional charges.

DOMESTIC -

Products are shipped Monday through Friday via UPS/FedEx/USPS. The estimated delivery time is 1-6 business days depending on location. If “Free Shipping” is offered, it will be by Ground only and within USA Continental States Only (48 States). There will be a surcharge on shipments to Hawaii, Alaska, Puerto Rico and APO/FPO addresses. After you have made a purchase, the surcharge will be calculated using the parcel’s weight and size. Network Devices Inc ships the product the same day of receiving an order. Otherwise you will a receive notification of delay or cancellation of said order.
 